Filter Recommendations

Pump life increases with fluid purity. Micropump recommends using as fine a mesh as possible. The recommendations below are based on Micropump’s experience in optimizing pump life.

Filter Location

Open System: Inlet side of pump
Closed Loop System: Inlet or outlet side of pump

 

Filter Type/Size
Series GA
Series GAT
  • 5 Micron** (≤2 psid [0.14 bar] pressure drop)
  • Canister style (Fig. 2) or Fine Mesh style (Fig. 1)
Series GJ

Series GL

  • 40 Micron* – Soft particles (≤ 4 psid [0.27 bar] pressure drop)
  • 5 Micron* – Hard particles (≤ 4 psid [0.27 bar] pressure drop)
  • Canister Style
Series GB

Series GC
Series GD

  • 40 Micron* – Soft particles (≤ 2 psid [0.27 bar] pressure drop)
  • 5 Micron* – Hard particles (≤ 2 psid [0.27 bar] pressure drop)
  • Canister Style
Series CA
  • 50 Micron* (no pressure drop)
  • Mesh Style

*Micron = 4 x 10-5 inches
**Micron = 10-6 meter

   Fig. 1
 Mesh Style

Fig. 2
Canister Style

Troubleshooting

If units will not prime:

  • Reduce pressure drop across filters
  • Remove clogged passages or debris

When pumping higher viscosity fluids:

  • Increase the size of the filter to insure pressure drop stays within an acceptable range


 




 