Filter Recommendations
Pump life increases with fluid purity. Micropump recommends
using as fine a mesh as possible. The recommendations below are
based on Micropump’s experience in optimizing pump life.
Filter Location
Open System: Inlet side of pump
Closed Loop System: Inlet or outlet side of pump
Filter Type/Size
Series
GA
Series GAT |
- 5 Micron** (≤2 psid [0.14 bar] pressure drop)
- Canister style (Fig. 2) or Fine Mesh style (Fig. 1)
|
| Series
GJ
Series GL
|
- 40 Micron* – Soft particles (≤ 4 psid [0.27
bar] pressure drop)
- 5 Micron* – Hard particles (≤ 4 psid [0.27
bar] pressure drop)
- Canister Style
|
| Series
GB
Series GC
Series GD |
- 40 Micron* – Soft particles (≤ 2 psid [0.27
bar] pressure drop)
- 5 Micron* – Hard particles (≤ 2 psid [0.27
bar] pressure drop)
- Canister Style
|
| Series
CA |
- 50 Micron* (no pressure drop)
- Mesh Style
|
*Micron = 4 x 10-5 inches
**Micron = 10-6 meter
Fig. 1
Mesh Style |
Fig. 2
Canister Style |
Troubleshooting
If units will not prime:
- Reduce pressure drop across filters
- Remove clogged passages or debris
When pumping higher viscosity fluids:
- Increase the size of the filter to insure pressure drop stays
within an acceptable range
|